FalehSec Exploited-vulnerability triage · joined from CISA KEV, NVD CVSS and EPSS

CVE-2026-83548

SonicWall · SMA1000 Appliances · SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability

Verdict
Patch first · actively exploited, reachable from the internet without credentials, and in the top 10% of CVEs by near-term exploitation probability

Added to CISA KEV 2026-09-02 · exploited in the wild for 25 days

What an attacker can reach How likely Time What CISA says to do Sources All 545

What an attacker can reach

CVSS 10.0 CRITICAL. The score is a summary; these three components are the part that decides whether something scanning the internet can use it.

Attack vectornetworkreachable over the network, with no local access needed
Privileges requirednoneneeds no credentials at all
User interactionnonecan be triggered with nobody interacting with the page or request
Base vectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
WeaknessCWE-441

This describes the vulnerability. It says nothing about whether your systems run it.

How likely

EPSS puts the probability of exploitation in the next 30 days at 0.0876, which places it in the top 10% of all tracked CVEs. The percentile is the more useful half: 0.18 in absolute terms sounds low until you know most of the internet-facing software in the world scores under that.

EPSS probability0.0876
Percentile0.950 — top 10%

Time

Added to KEV2026-09-02
Days exploited25
Federal remediation duenot set
Ransomware useno known ransomware campaign use

What CISA says to do

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. A remote unauthenticated attacker could potentially exploit this vulnerability to gain unauthorized access to sensitive functionality and perform unauthorized operations.